TECHNOLOGICAL TESTS FOR ORE ENRICHMENT |
---|
(*) This Analysis/Test is accredited by Turkish Accreditation Agency (TÜRKAK) in accordance with TS EN ISO/IEC 17025 Standard.
Analysis/Test Code |
Analysis/Test Name |
Method/Explanation |
Service Period (Workday) |
Sample Amount |
Service Fee (VAT Included) |
|
---|---|---|---|---|---|---|
35-30-TC-13 |
Sieve Analysis (Above 100 mesh; Dry) (Particle Size Distribution Analysis) |
Sieving is performed with 100 mesh sieve. (Particle size is more than 0,147 mm) Service fee is charged according to fraction number. Fraction number is determined as requested sieve number plus one. |
3 days |
1-5 kg |
95,00 TL /Fraction |
|
35-30-TC-14 |
*Sieve Analysis (Dry) (Particle Size Distribution Analysis) |
Performed according to TS 3479 ISO 2591-1 Standard. Sieving is performed with 9 mesh and/or 100 mesh (2mm and/or 0,147 mm) sieve. Service fee is charged according to fraction number. Fraction number is determined as requested sieve number plus one. |
3 days |
1-5 kg |
120,00 TL /Fraction |
|
35-30-TC-15 |
Sieve Analysis (Below 100 mesh; Dry) (Particle Size Distribution Analysis) |
Sieving is performed with 100 mesh sieve. (Particle size is below 0,147 mm) Service fee is charged according to fraction number. Fraction number is determined as requested sieve number plus one. |
3 days |
1-5 kg |
120,00 TL /Fraction |
|
35-30-TC-16 |
Sieve Analysis (Above 100 mesh; Wet) (Particle Size Distribution Analysis) |
Sieving is performed with 100 mesh sieve. (Particle size is more than 0,147 mm) Service fee is charged according to fraction number. Fraction number is determined as requested sieve number plus one. |
5 days |
1-5 kg |
140,00 TL /Fraction |
|
35-30-TC-17 |
*Sieve Analysis (Wet) (Particle Size Distribution Analysis) |
Performed according to TS 3479 ISO 2591-1 Standard. Sieving is performed with 9 mesh and/or 100 mesh (2mm and/or 0,147 mm) sieve. Service fee is charged according to fraction number. Fraction number is determined as requested sieve number plus one. |
5 days |
1-5 kg |
165,00 TL /Fraction |
|
35-30-TC-18 |
Sieve Analysis (Below 100 mesh; Wet) (Particle Size Distribution Analysis) |
Sieving is performed with 100 mesh sieve. (Particle size is below 0,147 mm) Service fee is charged according to fraction number. Fraction number is determined as requested sieve number plus one. |
5 days |
1-5 kg |
150,00 TL /Fraction |
|
35-30-TC-19 |
Dividing and Taking Representative Sample |
This process is for the samples with -30 mm particle size. Reduction and/or dividing is performed without damaging the representation. Service fee for the process to be performed to bring the sample to a suitable size should be additionally charged. |
1 day |
1-50 kg sample at -30 mm particle size |
35,00 TL/kg |
|
35-30-TC-20 (Sample acceptance cannot be made temporarily.) |
Shaking Table |
Each fraction size should be counted as one test. In case the sample is not at suitable size, service fee for the process to be performed to bring the sample to a suitable size should be additionally charged. If chemical and mineralogical analyses/tests are requested for the obtained product after the test, service fee for them are additionally charged. |
10 days |
10-50 kg |
470,00 TL/Test |
|
35-30-TC-21 (Sample acceptance cannot be made temporarily.) |
Jig |
Each fraction size should be counted as one test. In case the sample is not at suitable size, should fee for the process to be performed to bring the sample to a suitable size should be additionally charged. If chemical and mineralogical analyses/tests are requested for the obtained product after the test, service fee for them are additionally charged. |
10 days |
25-50 kg |
470,00 TL/Test |
|
35-30-TC-23 (Sample acceptance cannot be made temporarily.) |
Sink and Float Test (using separatory funnel) |
Heavy medium density is 2,96 gr/cm3. Each fraction size should be counted as one test. In case the sample is not at suitable size, service fee for the process to be performed to bring the sample to a suitable size should be additionally charged. If chemical and mineralogical analyses/tests are requested for the obtained product after the test, service fee for them are additionally charged. |
10 days |
0,2-1 kg |
1.410,00 TL/Test |
|
35-30-TC-24 (Sample acceptance cannot be made temporarily.) |
Multi-Gravity Separator (MGS) |
Each fraction size should be counted as one test. In case the sample is not at suitable size, service fee for the process to be performed to bring the sample to a suitable size should be additionally charged. If chemical and mineralogical analyses/tests are requested for the obtained product after the test, service fee for them are additionally charged. |
10 days |
50-200 kg |
880,00 TL/Test |
|
35-30-TC-25 (Sample acceptance cannot be made temporarily.) |
Sink and Float Test (in tank) (for coal) |
Flotation-submersion test for coal is performed in tanks containing liquid with 1,3-1,4-1,5-1,6-1,7-1,8-1,9 density. Analyses/Tests are performed on the products of flotation-submersion test. The results will be evaluated according to this. Service fee for bringing sample to the suitable size and analysis/test of the products should be additionally charged to this service fee. This service fee covers the sample that is studied with classified single fraction size. |
10 days |
50-100 kg |
14.100,00 TL |
|
35-30-TC-26 (Sample acceptance cannot be made temporarily.) |
Humphrey’s Spiral Test |
Each fraction size should be counted as one test. In case the sample is not at suitable size, service fee for the process to be performed to bring the sample to a suitable size should be additionally charged. If chemical and mineralogical analyses/tests are requested for the obtained product after the test, service fee for them are additionally charged. |
15 days |
50-200 kg |
2.350,00 TL/Test |
|
35-30-TC-27 (Sample acceptance cannot be made temporarily.) |
Low Intensity Dry Magnetic Separation (at laboratory scale) |
Each fraction size should be counted as one test. In case the sample is not at suitable size, service fee for the process to be performed to bring the sample to a suitable size should be additionally charged. If chemical and mineralogical analyses/tests are requested for the obtained product after the test, service fee for them are additionally charged. |
10 days |
10-50 kg |
410,00 TL/Test |
|
35-30-TC-29 (Sample acceptance cannot be made temporarily.) |
Low Intensity Wet Magnetic Separation (at laboratory scale) |
Each fraction size should be counted as one test. In case the sample is not at suitable size, service fee for the process to be performed to bring the sample to a suitable size should be additionally charged. If chemical and mineralogical analyses/tests are requested for the obtained product after the test, service fee for them are additionally charged. |
10 days |
10-50 kg |
590,00 TL/Test |
|
35-30-TC-31 (Sample acceptance cannot be made temporarily.) |
High Intensity Dry Magnetic Separation (at laboratory scale) |
Each fraction size should be counted as one test. In case the sample is not at suitable size, service fee for the process to be performed to bring the sample to a suitable size should be additionally charged. If chemical and mineralogical analyses/tests are requested for the obtained product after the test, service fee for them are additionally charged. |
10 days |
10-50 kg |
590,00 TL/Test |
|
35-30-TC-33 (Sample acceptance cannot be made temporarily.) |
High Intensity Wet Magnetic Separation (at laboratory scale) |
Each fraction size should be counted as one test. In case the sample is not at suitable size, service fee for the process to be performed to bring the sample to a suitable size should be additionally charged. If chemical and mineralogical analyses/tests are requested for the obtained product after the test, service fee for them are additionally charged. |
10 days |
10-50 kg |
530,00 TL/Test |
|
35-30-TC-35 |
Flotation Test (at laboratory scale) |
This test is performed only within the scope of full technological studies. Each cleaning test to be performed following a flotation test should be counted as a separate test. Service fee for the process to be performed to bring the sample to a suitable size should be additionally charged. Service fee for chemical and mineralogical analyses/tests to be performed after the test are additionally charged. |
10 days |
5 kg |
590,00 TL/Test |
|
35-30-TC-37 |
Filtration (+147 micron) |
Materials larger than 147 micron are filtered. |
5 days |
1-5 kg |
50,00 TL /Sample |
|
35-30-TC-38 |
Filtration (-147 microns) |
147 micron and fine materials are filtered. |
5 days |
1-5 kg |
60,00 TL /Sample |
|
35-30-TC-39 |
Scrubbing |
- |
5 days |
1 kg |
120,00 TL/Test |
|
35-30-TC-40 (Sample acceptance cannot be made temporarily.) |
Grindability Index Determination using Bond Mill |
Work index is performed. |
10 days |
50 kg |
2.050,00 TL /Sample |
|
35-30-TC-41 (Sample acceptance cannot be made temporarily.) |
Davis Tube Tester |
In case the sample is not at suitable size, service fee for the process to be performed to bring the sample to a suitable size should be additionally charged. If chemical and mineralogical analyses/tests are requested for the obtained product after the test, service fee for them are additionally charged. |
5 days |
1-2 kg |
470,00 TL/Test |
|
35-30-TC-42 |
Magnetite (Fe3O4) Determination using Satmagan Device. |
Result is given as % Magnetite (Fe3O4). Service fee for the process to be performed to bring the sample to a suitable size should be additionally charged. If chemical and mineralogical analyses/tests are requested for the obtained product after the test, service fee for them are additionally charged. |
5 days |
0,5-1 kg |
60,00 TL /Sample |
|
35-30-TC-44 |
Determination of Flowchart |
Determination of full technological test flowchart |
10 days |
- |
1.760,00 TL /Sample |
|
35-30-TC-45 |
Full Technology Studies |
These are the research studies that cover size reduction, taking representative sample, input analyses, processing tests, result analyses, evaluation and reporting according to the characteristics of the study. A contract is signed before these studies in case of an external application. 50% discount is applied to the analysis/tests to be made during the study. Moreover, an additional service fee will not be charged for the increase of analysis/test service fee that is up to 20% and may be necessary during the studies. |
Determined according to the characteristics of the study. |
Determined according to the characteristics of the study. |
Determined by all of the analyses/tests performed according to the characteristics of the study. |
|
Sample Storage |
Original sample of technological studies is stored for 6 months after reporting for free and after 6 months, stored for maximum another 36 months in exchange of a service fee upon the request of the applicant. |
- | Up to 50 kg | 70,00 TL /Month | ||
- |
Between (50-100) kg |
60,00 TL /Month | ||||
- | 100 kg and more | 50,00 TL /Month | ||||
35-30-TC-46 (Sample acceptance cannot be made temporarily.) |
Zeta Potential Measurement |
Push-pull value between particles is determined and particles behaviors are examined in processes such as flotation. Particles size should be -10 µm. In case the sample is not at suitable size, service fee for the process to be performed to bring the sample to a suitable size (-10 µm) should be additionally charged. |
3 days |
100-500 g at -10 µ particles size |
400,00 TL /pH 150,00 TL for each additional pH at pH scan |
|
35-30-TC-47 (Sample acceptance cannot be made temporarily.) |
Stove Combustion Test |
Stove Combustion Test is suitable for briquette coal samples produced lignite and lignite powder. Analyses/tests are performed during stove combustion test. The results will be evaluated according to this. Service fees of the analyses/tests are included in this service fee. |
5 days |
10-20 kg |
8.230,00 TL /Test |