PRECIOUS METAL (NOBLE METAL) ANALYSES |
---|
(*) This Analysis/Test is accredited by Turkish Accreditation Agency (TÜRKAK) in accordance with TS EN ISO/IEC 17025 Standard.
(a) Results above the upper detection Iimit are given in accordance with the AJ-18 code.
Analysis/Test Code |
Analysis/Test Name
|
Detection Limit
|
Method/Explanation
|
Service Period (Workday) |
Sample Amount |
Service Fee (Including VAT) |
||
---|---|---|---|---|---|---|---|---|
Lower
|
Upper
|
|||||||
35-30-AJ-16 |
*Rock, Soil, Sand Samples | *Au (Gold) |
0,1 ppm
|
a2 ppm |
In-house method (Fire Assay, Acid Dissolution followed by ICP-MS) Fire Assay Method + Cupellation Method + Acid Dissolution + Analysis by ICP-MS |
7 days
|
Pulverized 150 g,
not pulverized 0,5 - 2 kg
|
320,00 TL /Sample |
35-30-AJ-18 |
*Rock, Soil, Sand Samples | *Au (Gold) |
0,5 g/ton
|
-
|
In-house method (Gravimetric Method after Fire Assay) Fire Assay Method + Cupellation Method + Gravimetric Analysis |
7 days
|
Pulverized 150 g,
not pulverized 0,5 - 2 kg
|
400,00 TL /Sample |
*Ag (Silver) |
2,0 g/ton
|
-
|
||||||
35-30-AJ-20 |
Rock, Ore, Soil, Sand Samples | Pt (Platinum) |
0,05 ppm
|
1000 ppm
|
In-house method (Fire Assay Method + Cupellation Method + Analysis by ICP-MS) |
7 days
|
Pulverized 50 g,
not pulverized 0,5 - 2 kg
|
400,00 TL for one parameter, and 20,00 TL for each additional parameter (For one sample) |
Pd (Palladium) |
0,3 ppm
|
1000 ppm
|
||||||
Ir (Irridium) |
0,3 ppm
|
1000 ppm
|
||||||
Ru (Ruthenium) |
0,3 ppm
|
1000 ppm
|
||||||
Rh (Rhodium) |
0,3 ppm
|
1000 ppm
|
||||||
35-30-AJ-23 |
Alloy, Anode Slime, Jewelry Slag Samples | Au (Gold) |
0,5 g/ton
|
-
|
In-house method (Fire Assay Method + Cupellation Method + Gravimetric Analysis) |
7 days
|
250 g
|
400,00 TL /Sample |
Ag (Silver) |
2,0 g/ton
|
-
|
||||||
35-30-AJ-24 |
Anode Slime Samples | Cu (Copper) |
-
|
-
|
Dissolution by TS-ISO 14869-1 Standard followed by ICP-OES Fire Assay and Gravimetric Analysis Fire Assay Method + Analysis by ICP-MS |
7 days
|
200 g
|
2.000,00 TL /Sample |
Se (Selenium) |
-
|
-
|
||||||
Te (Tellerium) |
-
|
-
|
||||||
As (Arsenic) |
-
|
-
|
||||||
Au (Gold) |
-
|
-
|
||||||
Ag (Silver) |
-
|
-
|
||||||
Sb (Antimony) |
-
|
-
|
||||||
Bi (Bismuth) |
-
|
-
|
||||||
Sn (Tin) |
-
|
-
|
||||||
*Pt (Platinum) |
0,3 ppm
|
2 ppm
|
||||||
*Pd (Palladium) |
0,6 ppm
|
2 ppm
|
||||||
35-30-AJ-47 |
High Carbon Samples | Au (Gold) |
0,5 g/ton
|
-
|
Fire Assay Method +
Cupellation Method+
Gravimetric Analysis
|
7 days
|
200 g
|
480,00 TL /Sample |
Ag (Silver) |
2,0 g/ton
|
-
|
||||||
35-30-AJ-60 (Applications outside the institution are not accepted.)
(Only Technology
Coordinator
can make request.)
|
Rock, Soil, Sand Samples | Au (Gold) | 0,05 ppm | a2 ppm |
In-house method (Fire Assay, Acid Dissolution followed by AAS/ICP-MS) Fire Assay Method + Cupellation Method + Acid Dissolution + Analysis by AAS/ICP-MS |
7 days |
Pulverized 150 g,
not pulverized 0,5 - 2 kg
|