OTHER TECHNOLOGICAL TESTS 

 

Analysis/Test Code

Analysis/Test Name

Method/Explanation

Service Period (Workday)

Sample Amount

Service Fee

(VAT Included)

35-30- TS-98

DTA-TG Thermograms

Test temperature and heating rate should be indicated.

7 days

15-20 g powder sample

1.060,00 TL/Sample

35-30-TS-99

Determination of Thermal Conductivity Coefficient

[between (-10) ºC - (+20) ºC]

Analysis/test result is given in 3 (three) temperature points.

7 days

At least 2 samples at the diameter of 2 inches (~5 cm).

415,00 TL for 3 (three) temperature points.

85,00 TL for every point after 3 (three) points.

35-30-TS-100

Determination of Thermal Conductivity Coefficient

[between (+21) ºC - (+100) ºC]

Analysis/test result is given in 3 (three) temperature points.

7 days

At least 2 samples at the diameter of 2 inches (~5 cm).

325,00 TL for 3 (three) temperature points.

65,00 TL for every point after 3 (three) points.

35-30-TS-101

Determination of Thermal Conductivity Coefficient

[between (+101) ºC -(+150) ºC]

Analysis/test result is given in 3 (three) temperature points.

7 days

At least 2 samples at the diameter of 2 inches (~5 cm).

470,00 TL for 3 (three) temperature points.

85,00 TL for every point after 3 (three) points.

35-30-TS-102

Rock/Ore Grinding with Attritor

Grinding is performed with dry or wet method.

a) Analysis/test with TS-01 code are performed.

Sample type, requested test speed and duration (cycle/minute) or requested particle size should be indicated in the Analysis/Test Application Form.

5 days

100 g

325,00 TL/Sample

35-30-TS-103

Technological Researches of Industrial Raw Materials

These researches include physical and chemical processes after size shrinkage process according to the characteristic of the study.

50% discount will be made for the analysis/test to be performed durind the study.

Moreover, an additional service fee will not be charged for the increase of analysis/test service fee that is up to 20% and may be necessary during the studies.

Determined according to the characteristics of the study.

Determined according to the characteristics of the study.

Determined according to the characteristics of the study.

35-30-TS-126

Isostatic Pressing Process

Performed with wet method on pre-shaped sample.

Pressing pressure between 0-200 Mpa and its duration should be indicated in the Analysis/Test Application Form.

5 days

Test chamber of the device is 80x160 diameter x size, so the sample size should be suitable for the chamber.

470,00 TL/Sample