INDUSTRIAL RAW MATERIAL AND ORE ANALYSES - CLASSICAL (WET) METHODS |
---|
If the analysis mathod requested for the sample is not suitable for the sample structure, the detection of desired elements/compounds and/or existing standards/device programs, it is analyzed with the appropriate one. Analysis/Test Report is prepared according to the Analysis/Test Code corresponding to this analysis method. Due to the fact, prices may vary.
(*) This Analysis/Test is accredited by Turkish Accreditation Agency (TÜRKAK) in accordance with TS EN ISO/IEC 17025 Standard.
Analysis/Test Code |
Analysis/Test Name |
Detection Limit |
Method/Explanation |
Service Period (Workday) |
Sample Amount |
Service Fee (Including VAT) |
||
---|---|---|---|---|---|---|---|---|
Lower |
Upper |
|||||||
35-30-AA-01 |
Carbonate Minerals such as Calcite, Dolamite, Magnesite |
SiO2 (Silicon dioxide) |
0,05% |
- |
ICP-OES Analysis + Gravimetric Analysis |
10 days |
Pulverized 100 g, not pulverized 0,5-2 kg |
All for 960,00 TL or 200,00 TL for one parameter, and 150,00 TL for each additional parameter (For one sample) |
Fe2O3 [Iron (III) oxide] |
0,01% |
- |
||||||
Al2O3 [Aluminum (III) oxide] |
0,01% |
- |
||||||
CaO (Calcium oxide) |
0,01% |
- |
||||||
MgO (Magnesium oxide) |
0,01% |
- |
||||||
CO2 (Carbon dioxide) |
0,05% |
- |
||||||
*Loss on ignition (LOI) |
0,2% |
- |
In-House Method Accredited results are given for the samples in the detection range of 0.2 - 45%. LOI also includes the CO2 value. CO2 parameter should not be evaluated separately. |
|||||
35-30-AA-02 |
Silicate Minerals such as Quartz, Feldspar |
Al2O3 [Aluminum (III) oxide] |
0,01% |
- |
(Fusion Method)
Volumetric Analysis + Gravimetric Analysis + Analysis by ICP-OES |
10 days |
Pulverized 100 g, not pulverized 0,5-2 kg |
All for 960,00 TL or 200,00 TL for one parameter, and 150,00 TL for each additional parameter (For one sample) |
Fe2O3 [Iron (III) oxide] |
0,01% |
- |
||||||
CaO (Calcium oxide) |
0,01% |
- |
||||||
MgO (Magnesium oxide) |
0,01% |
- |
||||||
Na2O (Sodium oxide) |
0,01% |
- |
||||||
K2O (Potassium oxide) |
0,01% |
- |
||||||
TiO2 (Titanium dioxide) |
0,01% |
- |
||||||
*SiO2 (Silicon dioxide) |
0,05% |
- |
In-House Method Fusion Method (The detection range of 37-90% accredited.) |
|||||
*Loss on ignition (LOI) |
0,2% |
- |
In-House Method Accredited results can be given for the samples in the detection range of 0.2-45%. |
|||||
35-30-AA-03 |
*Gypsum |
*CaO (Calcium oxide) |
- |
- |
In-House Method (Gravimetric Method) |
7 days |
Pulverized 100 g, not pulverized 0,5-2 kg |
All for 400,00 TL or
200,00 TL for one parameter |
*SO3 (Sulphite) |
- |
- |
||||||
*Water Determination (H2O-) (Crystal Water) (380 ºC) |
- |
- |
||||||
35-30-AA-04 |
*Rock, Soil and Sand Samples |
*Fetop (Total Iron) |
12% |
70% |
In-House Method (Dichromate Titration Method)
|
5 days |
Pulverized 100 g, not pulverized 0,5-2 kg |
All for 480,00 TL or
200,00 TL for one parameter |
*Fe+2 (Iron +2) |
0,2% |
21% |
||||||
*Fe+3 (Iron +3) |
12% |
70% |
||||||
35-30-AA-05 |
Rock, Soil and Sand Samples |
Fetop (Total Iron) |
1,2% |
- |
Dichromate Titration Method |
5 days |
Pulverized 100 g, not pulverized 0,5-2 kg |
All for 400,00 TL or 150,00 TL for one parameter |
Fe+2 (Iron +2) |
0,2% |
- |
||||||
Fe+3 (Iron +3) |
1,2% |
- |
||||||
35-30-AA-06 |
Rock, Soil and Sand Samples |
Fe2O3 [Iron (III) oxide] |
0,01% |
- |
Analysis by ICP-OES |
5 days |
Pulverized 100 g, not pulverized 0,5-2 kg |
250,00 TL /Sample |
35-30-AA-07 |
Sponge Iron/Directed Reduced Iron Samples |
Feº (Metallic Iron) |
1,2% |
- |
Volumetric Analysis + Gravimetric Analysis |
5 days |
Pulverized 100 g, not pulverized 0,5-2 kg |
250,00 TL /Sample |
35-30-AA-08 |
Pyrite |
Fetop (Total Iron) |
1,2% |
- |
Gravimetric Analysis |
7 days |
Pulverized 100 g, not pulverized 0,5-2 kg |
All for 400,00 TL or 150,00 TL for one parameter |
S (Sulfur) |
0,05% |
- |
||||||
35-30-AA-09 |
Rock, Soil, Ore Samples |
Cu (Copper) |
0,5% |
- |
Gravimetric Analysis + Volumetric Analysis + Electrolysis (For values above 5%) |
7 days |
Pulverized 100 g, not pulverized 0,5-2 kg |
300,00 TL for first element, and 250,00 TL for each additional element |
Pb (Lead) |
0,5% |
- |
||||||
Zn (Zinc) |
5% |
- |
||||||
35-30-AA-10 |
Rock, Soil and Sand Samples |
C (Carbon) |
0,05% |
8% |
By Carbon-Sulfur Analyzer. SO3 and SO4 find by total S based calculation method. |
7 days |
Pulverized 100 g, not pulverized 0,5-2 kg |
160,00 TL /Parameter |
S (Sulfur) |
0,05% |
12% |
||||||
SO3 (Sulfite) |
0,05% |
30% |
||||||
SO4 (Sulfate) |
0,05% |
36% |
||||||
35-30-AA-11 |
Gypsum |
Crystal Water H2O- (380 ºC) |
0,05% |
- |
Gravimetric Analysis |
7 days |
Pulverized 100 g, not pulverized 0,5-2 kg |
190,00 TL /Sample |
35-30-AA-12 |
Carbonate Minerals such as Calcite, Dolamite, Magnesite |
CO2 (Carbon dioxide) |
0,05% |
12,0% |
Carbon-Sulphur Determination instrument and total carbon calculation methods are used if the CO2 amount is up to 25%. If the CO2 is above 25%, Loss on Ignition calculation is applied. |
7 days |
Pulverized 100 g, not pulverized 0,5-2 kg |
160,00 TL /Sample |
35-30-AA-13 |
Rock, Soil and Sand Samples |
pH |
|
- |
pH meter |
3 days |
Pulverized 100 g, not pulverized 0,5-2 kg |
80,00 TL /Sample |
35-30-AA-14 |
Soil, Anode Sludge, Jeweler Slag, Activated Carbon Samples |
Moisture |
0,05% |
- |
Gravimetric Analysis |
3 days |
The sample should be placed tightly in a closed container suitable for weighing without any grinding and drying pre-treatments, and after the lid is taped, it should be placed in 2 (two) bags and sent. Sample amount should be 0.5-2 kg. |
110,00 TL /Sample |
35-30-AA-50 |
Carbonate Minerals such as Calcite, Dolamite, Magnesite |
Matter insoluble in acid |
0,05% |
- |
Dissolution |
5 days |
Pulverized 100 g, not pulverized 0,5-2 kg |
All for 160,00 TL or 100,00 TL for one parameter (For one sample) |
Matter soluble in acid |
0,05% |
- |
||||||
35-30-AA-51 |
Carbonate Minerals such as Calcite, Dolamite, Magnesite |
Matter insoluble in water |
0,05% |
- |
Dissolution |
5 days |
Pulverized 100 g, not pulverized 0,5-2 kg |
All for 160,00 TL or 100,00 TL for one parameter (For one sample) |
Matter soluble in water |
0,05% |
- |
||||||
35-30-AA-54 |
Boron Minerals |
B2O3 (Boron trioxide) |
3% |
- |
Volumetric Analysis |
7 days |
Pulverized 100 g, not pulverized 0,5-2 kg |
160,00 TL /Sample |
35-30-AA-55 | Rock, Soil, and Ore Samples | Sb (Antimony) | 5% | - | Volumetric Analysis | 7 days | Pulverized 100 g, not pulverized 0,5-2 kg |
160,00 TL /Sample |
35-30-AA-56 |
Chromium in the Ore |
Cr2O3 (Chromium Trioxide) |
6% |
95% |
Fusion Method+ Volumetric analysis |
5 days |
Pulverized 100 g, not pulverized 0,5-2 kg |
160,00 TL /Sample |